Case: When the split molding machine is pressuring, the pressure dropping to show from the oil gauge, the machine cannot press properly.
Now check one by one:
1. Check the outside surface of the machine, if there is any place oil leak:
1-1. Main cylinder
1-2. Air-released hole at the backside of cylinder (Picture 1)
Picture 1
1-3. Air gauge (Picture 2 )
1-4. Pressure relieve valve (Picture 2)
Picture 2
2. If there is no oil leak from the above mentioned parts, then come to check the Pressure Relieve Valve.
Open the valve and check if the rubber seal is broken or not. If the rubber seal is broken, there will be oil leak, need to replace new seal.
If the rubber seal is not broken, then clean the valve by water and air gun, to clean the foreign matters out if have.
फिर इस वाल्व को वापस बदल दें।
3. रिलीव वाल्व को बदलने के बाद, यदि दबाव अभी भी गिरता है, तो चेक-वाल्व की जांच करने के लिए आता है। वाल्व खोलें और इसे साफ करें।
4. चेक-वाल्व को बदलने के बाद, और समस्या अभी भी हल नहीं हुई है, फिर अगला भाग, एयर-रिलीज वाल्व की जांच करने के लिए आता है:
इस हिस्से को ठीक से और सावधानी से हटाने की जरूरत है, क्योंकि तेल की सील अलग-अलग आकार की होती है (हमारे पास यह दिखाने के लिए एक वीडियो है कि कैसे निकालना है):
इस वाल्व को हटाने के बाद, और फिर इस वाल्व को हाथ में चलाएं, हम देख सकते हैं कि वाल्व को ठीक से बंद करने से रोकने के लिए अंदर कोई बाहरी मामला है या नहीं, और मशीन का दबाव कम हो जाता है।
2 दिनों के भीतर (2 देशों के बीच समय के अंतर के कारण), मेलामाइन टेबलवेयर स्प्लिट मोल्डिंग मशीन के प्रेशर ड्रॉप्स की समस्या आखिरकार हल हो गई, मेलामाइन टेबलवेयर फैक्ट्री के इंजीनियरों की टीम के सहयोग कार्य के लिए धन्यवाद।